UPS Power System

UPS Power System

Double-Conversion Online · Zero Transfer Time · Intelligent Battery Management · High Output Power Factor

Thank you for reading this post, don't forget to subscribe!
WattPower UPS Power System

Product Overview

The WattPower UPS Power System is a high-reliability, double-conversion online uninterruptible power supply designed for mission-critical loads in substations, data centers, industrial plants, and commercial facilities.

With zero transfer time, high output power factor (0.9/1.0), intelligent battery management system (BMS), and comprehensive communication capabilities including IEC 61850, it ensures seamless power protection for critical equipment — eliminating downtime risks from grid disturbances.

Key Features

  • Double-Conversion Online Topology — True double-conversion design with zero transfer time (0ms) from bypass to inverter, providing the highest level of power protection
  • High Output Power Factor — Output power factor of 0.9 / 1.0 (model dependent), delivering more real power to critical loads compared to standard 0.8 PF UPS units
  • Intelligent Battery Management — Temperature-compensated charging, automatic battery test, deep-discharge protection, and battery health monitoring for extended battery life
  • Wide Input Voltage Range — Broad input voltage range (380V AC ±25%) minimizes battery usage, extending battery service life and reducing maintenance
  • Comprehensive Communication — RS485/RS232/Ethernet with MODBUS, IEC 60870-5-103, and IEC 61850 protocol support for substation and industrial automation integration
  • Parallel Redundancy (Optional) — N+1 parallel redundant operation for increased system reliability and capacity expansion without downtime

Technical Parameters

UPS Power System
Input
Input Voltage 380V AC, 3Ph+N+PE, ±25%
Input Frequency 50Hz ±10%
Input Power Factor (with PFC) ≥0.99
THDi (full load) ≤3%
Bypass Input 380V AC ±15%, 3Ph+N+PE
Output
Rated Power Capacity 10kVA ~ 200kVA (configurable)
Output Power Factor 0.9 / 1.0
Output Voltage 380V AC / 220V AC (configurable)
Output Voltage Regulation ≤±1% (steady state)
Output Frequency (battery mode) 50Hz ±0.1%
Output Waveform Pure sine wave
THDu (linear load) ≤2%
Crest Factor 3:1
Transfer Time (bypass → inverter) 0ms (online double-conversion)
Battery
Battery Type VRLA (AGM/GEL) / LFP (optional)
DC Bus Voltage 360V DC ~ 480V DC (model dependent)
Charging Method 3-stage: CC → CV → Float
Charging Current 0.1C ~ 0.2C (configurable)
Backup Time Configurable per battery capacity
Communication & Monitoring
Monitoring Interface LCD display + touchscreen HMI (optional)
Communication Ports RS485 / RS232 / Ethernet / Dry contacts
Supported Protocols MODBUS / IEC 60870-5-103 / IEC 61850
Parallel Operation Up to 4 units (N+1, optional)
General Data
Ingress Protection IP20 / IP30 (cabinet dependent)
Operating Temperature 0°C ~ +40°C
Storage Temperature -25°C ~ +55°C
Relative Humidity 0~95% (non-condensing)
Noise Level ≤60dB (1m distance, depending on model)
Cooling Method Temperature-controlled fan cooling

Core Advantages

Zero Transfer Time

  • True online double-conversion topology
  • 0ms transfer time (bypass → inverter)
  • Pure sine wave output, ≤2% THDu
  • Protects sensitive electronic loads
📊

High Output Power Factor

  • Power factor 0.9 / 1.0 output
  • More real power vs. standard 0.8 PF UPS
  • Higher usable capacity per kVA
  • Better ROI for critical loads
🔋

Intelligent Battery Management

  • Temperature-compensated charging
  • Automatic battery capacity test
  • Deep-discharge protection
  • Battery health status monitoring
🛡️

Wide Input Voltage Range

  • 380V AC ±25% input range
  • Reduces battery discharge frequency
  • Extends battery service life
  • Generator-compatible input
🌐

Flexible Communication

  • RS485, RS232, Ethernet interfaces
  • MODBUS standard protocol
  • IEC 60870-5-103 for power systems
  • IEC 61850 for substation integration
🔗

N+1 Parallel Redundancy

  • Up to 4 units parallel operation
  • N+1 redundant configuration
  • Hot-swappable maintenance (with bypass)
  • Capacity expansion without downtime

Application Scenarios

Power Substations
🏢
Data Centers
🏭
Industrial Automation
🏥
Hospitals & Healthcare
🚉
Railway & Transit
🏨
Commercial Buildings
🛢️
Oil & Gas Facilities
📡
Telecom & Data Comms

Need Uninterruptible Power Protection?

Contact our engineering team for UPS sizing, battery backup calculation, and customized power protection solutions.

Contact Us Now
Email: sales@wattpower.com.cn  |  WhatsApp: +86 15916287178