UPS Power System
Double-Conversion Online · Zero Transfer Time · Intelligent Battery Management · High Output Power Factor
Thank you for reading this post, don't forget to subscribe!
Product Overview
The WattPower UPS Power System is a high-reliability, double-conversion online uninterruptible power supply designed for mission-critical loads in substations, data centers, industrial plants, and commercial facilities.
With zero transfer time, high output power factor (0.9/1.0), intelligent battery management system (BMS), and comprehensive communication capabilities including IEC 61850, it ensures seamless power protection for critical equipment — eliminating downtime risks from grid disturbances.
Key Features
- Double-Conversion Online Topology — True double-conversion design with zero transfer time (0ms) from bypass to inverter, providing the highest level of power protection
- High Output Power Factor — Output power factor of 0.9 / 1.0 (model dependent), delivering more real power to critical loads compared to standard 0.8 PF UPS units
- Intelligent Battery Management — Temperature-compensated charging, automatic battery test, deep-discharge protection, and battery health monitoring for extended battery life
- Wide Input Voltage Range — Broad input voltage range (380V AC ±25%) minimizes battery usage, extending battery service life and reducing maintenance
- Comprehensive Communication — RS485/RS232/Ethernet with MODBUS, IEC 60870-5-103, and IEC 61850 protocol support for substation and industrial automation integration
- Parallel Redundancy (Optional) — N+1 parallel redundant operation for increased system reliability and capacity expansion without downtime
Technical Parameters
| UPS Power System | |
|---|---|
| Input | |
| Input Voltage | 380V AC, 3Ph+N+PE, ±25% |
| Input Frequency | 50Hz ±10% |
| Input Power Factor (with PFC) | ≥0.99 |
| THDi (full load) | ≤3% |
| Bypass Input | 380V AC ±15%, 3Ph+N+PE |
| Output | |
| Rated Power Capacity | 10kVA ~ 200kVA (configurable) |
| Output Power Factor | 0.9 / 1.0 |
| Output Voltage | 380V AC / 220V AC (configurable) |
| Output Voltage Regulation | ≤±1% (steady state) |
| Output Frequency (battery mode) | 50Hz ±0.1% |
| Output Waveform | Pure sine wave |
| THDu (linear load) | ≤2% |
| Crest Factor | 3:1 |
| Transfer Time (bypass → inverter) | 0ms (online double-conversion) |
| Battery | |
| Battery Type | VRLA (AGM/GEL) / LFP (optional) |
| DC Bus Voltage | 360V DC ~ 480V DC (model dependent) |
| Charging Method | 3-stage: CC → CV → Float |
| Charging Current | 0.1C ~ 0.2C (configurable) |
| Backup Time | Configurable per battery capacity |
| Communication & Monitoring | |
| Monitoring Interface | LCD display + touchscreen HMI (optional) |
| Communication Ports | RS485 / RS232 / Ethernet / Dry contacts |
| Supported Protocols | MODBUS / IEC 60870-5-103 / IEC 61850 |
| Parallel Operation | Up to 4 units (N+1, optional) |
| General Data | |
| Ingress Protection | IP20 / IP30 (cabinet dependent) |
| Operating Temperature | 0°C ~ +40°C |
| Storage Temperature | -25°C ~ +55°C |
| Relative Humidity | 0~95% (non-condensing) |
| Noise Level | ≤60dB (1m distance, depending on model) |
| Cooling Method | Temperature-controlled fan cooling |
Core Advantages
⚡
Zero Transfer Time
- True online double-conversion topology
- 0ms transfer time (bypass → inverter)
- Pure sine wave output, ≤2% THDu
- Protects sensitive electronic loads
📊
High Output Power Factor
- Power factor 0.9 / 1.0 output
- More real power vs. standard 0.8 PF UPS
- Higher usable capacity per kVA
- Better ROI for critical loads
🔋
Intelligent Battery Management
- Temperature-compensated charging
- Automatic battery capacity test
- Deep-discharge protection
- Battery health status monitoring
🛡️
Wide Input Voltage Range
- 380V AC ±25% input range
- Reduces battery discharge frequency
- Extends battery service life
- Generator-compatible input
🌐
Flexible Communication
- RS485, RS232, Ethernet interfaces
- MODBUS standard protocol
- IEC 60870-5-103 for power systems
- IEC 61850 for substation integration
🔗
N+1 Parallel Redundancy
- Up to 4 units parallel operation
- N+1 redundant configuration
- Hot-swappable maintenance (with bypass)
- Capacity expansion without downtime
Application Scenarios
⚡
Power Substations
🏢
Data Centers
🏭
Industrial Automation
🏥
Hospitals & Healthcare
🚉
Railway & Transit
🏨
Commercial Buildings
🛢️
Oil & Gas Facilities
📡
Telecom & Data Comms
Need Uninterruptible Power Protection?
Contact our engineering team for UPS sizing, battery backup calculation, and customized power protection solutions.
Contact Us Now
Email: sales@wattpower.com.cn | WhatsApp: +86 15916287178